ICS-20B series electronic belt scale
Jiangsu Huaqi Electric Co., Ltd. (formerly Jiangsu Ramsey Electric Technology Co., Ltd.) fully absorbed applied the weighing process of the world famous brand Thermo Ramsey, developed produced various types of electronic belt scales with precision, developed belt scale application software for users. In order to make the weighing data more effective, reduce production costs reduce costs.
Product Details
ICS20B series belt scales have a dynamic cumulative error of less than ±1.0% are used to weigh belt conveyors in general factories to accurately control the amount of feed to crushers, ball mills, sieving machines other processes. It can also be used to monitor production volume, control product loading, monitor product inventory.
ICS20B series belt scales are mainly composed of four parts: ICS20B fully suspended weighing bridge supported by two trunnions, a weighing sensor, digital speed sensor, 2000 series totalizer.
ICS20B weighing bridge
The ICS20B weighing bridge is equipped with a single set of heavy rollers on the lever, supported by a single load cell, the outer support is supported by a frictionless trunnion fulcrum. This closed device can prevent shock, moisture, corrosion, prevent material accumulation. The problems caused by the use of knife edge devices bearing devices do occur in the environment.
The main beam of the weighing bridge is made of rectangular steel pipes, which makes the whole weighing bridge have high enough rigidity, small self-weight, the smallest ash accumulation area. The weighing bridge can be directly installed in belt conveyor racks of various widths, located between the upper lower belts, does take up space. It is a unit that has been assembled in the factory can be quickly easily installed calibrated.
Technical Parameters
▪ Measuring accuracy: ±1.0% ▪ Weighing range: 0~6000t/h ▪ Belt width: 500~2200mm
▪ Belt speed: 0.01~4.0m/s ▪ Belt conveyor inclination angle: 0°~18° ▪ Remote transmission: 1200m
Working installation environment
▪ Ambient temperature: Mechanical: -20°C~+50°C Instrument: -20°C~+40°C
▪ Power supply voltage: 220VAC (+10%~-15%) 50HZ±2%
Dimensions
Note: The size of the bandwidth listed in the table is determined according to the actual rack
Installation diagram